|
Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Current Type: | AC |
| Phase: | Three Phase |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency








Specifications:
| Model | TRBW-S 30KVA | TRBW-S 60KVA | TRBW-S 100KVA | TRBW-S 200KVA | TRBW-S 300KVA | TRBW-S 500KVA | TRBW-S 800KVA | TRBW-S 1000KVA | |
| Power | 30KVA | 60KVA | 100KVA | 200KVA | 300KVA | 500KVA | 800KVA | 1000KVA | |
| Technology | Triac - SCR- Thyristor control + Isolation transformer | ||||||||
| Phase | Three phase individual control | ||||||||
| Input | Wiring connection | 3P 4W+G 380V | |||||||
| Input voltage range | 380V±15% or ±20%, ±30% customized | ||||||||
| Input frequency | 50/60Hz | ||||||||
| Output | Output voltage | 380V (400V/415V Optional) | |||||||
| Output precision | ± 1~2% | ||||||||
| Delayed output | Voltage regulation before output (protect equipment from shock) | ||||||||
| Waveform distortion | No additional waveform distortion (static) | ||||||||
| Respond Time | ≤20ms | ||||||||
| Efficiency | ≥98% | ||||||||
| Display | Input current | A.B.C. three-phase true RMS LED touch display | |||||||
| Output voltage | A.B.C. three-phase true RMS line voltage, phase voltage switching | ||||||||
| Temperature | A.B.C. three-phase true RMS LED touch display | ||||||||
| Working condition | Voltage regulating mode / AC Mains mode | ||||||||
| Abnormal | Overvoltage, undervoltage, overtemperature, overload, failure | ||||||||
| Protection | High voltage | Output phase voltage exceeds 10% (245V), cut off the output or cut off the output configurable value (can be set according to actual requirements) | |||||||
| Low voltage | Output phase voltage exceeds 10% (195V), cut off the output or cut off the output configurable value (can be set according to actual requirements) | ||||||||
| Phase Failure | With (automatic switching) | ||||||||
| Wrong Phase Sequence | Can't switch on regulator | ||||||||
| Over current | Electronic detection and circuit breaker dual protection | ||||||||
| Manual Bypass | Fault uninterrupted automatic bypass | ||||||||
| Over load | Electronic detection, overload 1 second ~99 seconds can be set, 5 times rated current for 60 seconds | ||||||||
| Short circuit | Electronic detection and circuit breaker dual protection | ||||||||
| Delayed output | When the AC mains is switched on or the power is restored after power outage, the AVR output normally after 5 seconds time delaying | ||||||||
| Safety standards | Insulation Voltage | 3,000V / 60s | |||||||
| Insulation Resistance | >5MΩ | ||||||||
| Human-computer interface | Intelligent man-machine interface operation panel, easy to set and query various parameters | ||||||||
| Cooling Mode | Smart Cooling Fan | ||||||||
| IP Level | IP20 | ||||||||
| Environmental | Audible Noise | <65dB at 1m distance with full load | |||||||
| Stroage temperature | -15ºC - 45ºC | ||||||||
| Operating relative humidity | 10%-90%, non-condesing | ||||||||



